2
Firmware Tab
The Firmware Tab is where software revision upgrades
will be located. Clicking on the Firmware Tab will show the
following information:
Module Type: Shows the modules located in the console
that you are connected to. The information here will differ
depending on the conguration of the particular console
you are connected to (The Colibri console will only show
the Controller Module).
• A green button next to Module Type indicates that this
module currently has the latest version of software
installed.
• A red button next to the Module Type indicates that this
module does NOT currently have the latest version of
software installed. This can be veried by comparing the
Current Version with the Available Version numbers.
Slot: Is the physical location of the module in the console.
Current Version: Shows the version that is currently on
the module in the console that you are connected to.
Available Version: Lists the latest released versions of
software available to upgrade the software on the console.
Upgrading Firmware Steps
Assume as an example we want to upgrade the 4-20mA
Input Module. The console currently shows version 0.9.4
installed and version 0.9.8 is available.
Select the Upgrade Selected button after highlighting the
specic module to be upgraded.
For the example we would highlight the 4-20mA Input
Module and click the upgrade selected button. You will be
prompted with this warning.
Make sure historical data is saved. Then click OK. This will
bring up the conrmation screen.
Notice the Estimated time to complete, do not restart your
computer or console without allowing enough time for the
upgrade to complete.
Click OK to continue the upgrade process.
The bottom of the TSA Upgrade tool will show the status of
the upgrade process. There are three steps in the upgrade
process:
• “Upgrading (module name) Module” is the rst step and
will take the most time
• “Rebooting” is the second step in the upgrade process.
This step is rebooting the console.
• “Ready” is an indication that the console has been
upgraded and rebooted and has returned to normal
operation.
Important Notes:
• We recommend that each module be upgraded
individually. Do not use the Upgrade All Button.
• Upgrade the Controller Module rst and then the
Power Supply Module second, followed by the
remaining modules.
DTU Tab
The DTU tab is used for logging DTU signal quality only.
The output for the data log will be posted in a different
folder for each specic Controller Serial Number
under \ My Document \ TSA Upgrade
Tool with a lename of DTU Status Log.
Comentários a estes Manuais